In residential buildings above 11 metres the Responsible Person must make best endeavours to check flat entrance doors annually and communal fire doors quarterly. In other premises fire doors remain covered by the general duty to keep fire safety measures in efficient working order.
Duty summary
England & Wales
- Duty
- Fire Door Inspection
- Instrument
- Fire Safety (England) Regulations 2022, regulation 10
- Also
- article 17 of the Regulatory Reform (Fire Safety) Order 2005, the maintenance duty
- Standard
- BS 8214 for timber fire door assemblies, and Approved Document B
- Frequency
- Communal doors quarterly and flat entrance doors annually, in residential buildings above 11 metres
- Carried out by
- A competent person
- Enforced by
- Leicestershire Fire and Rescue Service
- Guide price
- £200 – £650 per survey
Guide price only. The firm we pass your enquiry to sets its own price once it knows the building.
For duty holders responsible for premises in Eyres Monsell, understanding the requirements for fire door inspection is an important part of maintaining fire safety. The postwar estate housing in Eyres Monsell, with its mix of residential blocks, local precinct shops, schools, and community premises in the LE2 postcode district, all contain fire doors that require regular checking. These doors are critical components in a building's fire safety strategy, designed to compartmentalise fire and smoke, protecting escape routes and allowing occupants time to evacuate safely. A fire door inspection in Eyres Monsell ensures these vital safety features remain in efficient working order.
Many premises within Eyres Monsell, from blocks of flats to shops and community halls, will have fire doors. For residential buildings, these include communal area doors and, in some cases, flat entrance doors. In commercial and public premises, fire doors are found in corridors, stairwells, and between different occupancy areas. The purpose of these inspections is to identify any defects or damage that could compromise their effectiveness in a fire. A fire door inspection in Eyres Monsell typically costs £200 to £650 per survey, with the exact figure depending on the building's specific characteristics. The quote for this service will be provided by the local firm we put you in touch with.
What a Fire Door Inspection Covers
A fire door inspection involves a detailed examination of all components of a fire door assembly to ensure they are fit for purpose and compliant with relevant standards. The scope of the work and, consequently, the price will vary based on several factors. These include the total number of fire doors in scope within the building, whether flat entrance doors are to be included in addition to communal doors, the building's height and tenure (e.g., residential, commercial, mixed-use), and the access arrangements for occupied flats if they are part of the inspection. Some firms may offer to quote for remedial work at the same visit, while others will provide a separate quotation following the inspection report.
The inspection typically covers:
- Door leaf: Checking for damage, correct thickness, and integrity.
- Door frame: so that it is properly installed and undamaged.
- Hinges: Verifying they are correctly fitted, secure, and in good condition.
- Closers: Confirming they close the door fully and effectively from any angle.
- Intumescent strips and smoke seals: Checking for presence, condition, and correct fitting.
- Glazing: Inspecting fire-rated glazing for integrity and correct installation.
- Ironmongery: so that all handles, locks, and other hardware are fire-rated and functioning correctly.
- Gaps: Measuring gaps around the door to ensure they are within permissible limits.
- Signage: Checking for correct and clear fire door signage.
How the enquiry works
Leicester Fire Risk Assessment is an enquiry service. We do not carry out the inspections ourselves. Our process is designed to connect you with a local fire safety firm that can provide the service you need.
- You send us the details: You provide us with information about your premises and your fire door inspection requirements.
- We pass them to a local firm: We forward your enquiry to a suitable local fire safety company.
- That firm contacts you with a quote: The chosen firm will get in touch with you directly to discuss your needs and provide a quotation for the inspection work.
- You deal with them directly: All subsequent communication, including scheduling and payment, will be directly between you and the fire safety firm.
The Legal Position on Fire Door Inspections
As a duty holder, you have a legal responsibility to ensure the fire safety measures within your premises are maintained in efficient working order. This includes fire doors. The primary legislation governing fire safety in England and Wales is the Regulatory Reform (Fire Safety) Order 2005 (FSO). Article 17 of the FSO places a general duty on the Responsible Person to ensure that fire safety facilities, equipment, and devices are subject to a suitable system of maintenance and are maintained in an efficient state, in efficient working order, and in good repair.
Specific requirements for fire doors were enhanced by the Fire Safety (England) Regulations 2022. Regulation 10 of these regulations introduces more stringent duties for Responsible Persons in multi-occupied residential buildings above 11 metres in height. For these buildings, the Responsible Person must undertake best endeavours to check all flat entrance doors at least annually and all communal fire doors at least quarterly. This includes so that the doors are compliant with the requirements of the FSO.
For other premises, such as commercial buildings, schools, or community centres, fire doors remain covered by the general duty under Article 17 of the FSO to keep fire safety measures in efficient working order. The inspection of fire doors should be carried out by a competent person. Competence typically means having sufficient training, experience, and knowledge in fire safety to be able to carry out the task. Guidance for the maintenance of timber fire door assemblies is often found in standards such as BS 8214, and the work is normally carried out against the guidance provided in Approved Document B of the Building Regulations.
It is important to remember that this page provides general information and is not specific advice for your particular building. The enforcement of fire safety legislation in Eyres Monsell sits with the local fire and rescue service or the local authority, as appropriate to the type of premises.
Questions duty holders ask
7 answers
How often must fire doors be checked?
For multi-occupied residential buildings over 11 metres, flat entrance doors must be checked annually and communal fire doors quarterly, as per the Fire Safety (England) Regulations 2022. For other premises, fire doors should be regularly inspected as part of the general maintenance required by the Regulatory Reform (Fire Safety) Order 2005, typically at least every six months, or more frequently if usage is high.
Does the 11 metre rule apply to my building?
The 11-metre rule applies to multi-occupied residential buildings where the floor of the top storey is 11 metres or more above ground level. If your building in Eyres Monsell fits this description, then the specific annual and quarterly inspection requirements for flat entrance and communal fire doors apply to you as the Responsible Person.
What makes a fire door fail an inspection?
A fire door can fail an inspection for various reasons, including excessive gaps around the door leaf, damaged or missing intumescent strips and smoke seals, non-compliant or faulty door closers that do not fully close the door, damaged frames or leaves, incorrect ironmongery, or the presence of unsuitable glazing. Any defect that compromises the door's ability to resist fire and smoke will result in a failure.
Can a general joiner carry this out?
Fire door inspections and any subsequent remedial work should be carried out by a competent person with specific knowledge and experience of fire door requirements and relevant standards. While a general joiner may have carpentry skills, they may not possess the specialised knowledge required for fire door compliance. It is advisable to use a firm with proven expertise in fire door safety.
Do I get a certificate or a report?
Following a fire door inspection, the firm you engage will typically provide a comprehensive report detailing the condition of each fire door inspected, any defects found, and recommended remedial actions. This report serves as your record of compliance and evidence that you have fulfilled your duty as the Responsible Person. Certificates are less common for inspections but may be issued for new installations or significant remedial work.
What is the typical cost for a fire door inspection?
The cost for a fire door inspection in Eyres Monsell typically ranges from £200 to £650 per survey. This figure can vary based on factors such as the number of doors, the type of building, and whether flat entrance doors are included. The specific quote will be provided by the local firm that contacts you after we pass on your enquiry.
Who carries out the inspection?
The inspection is carried out by a local fire safety firm that we connect you with. Leicester Fire Risk Assessment is an enquiry service; we do not employ assessors or engineers ourselves. We simply facilitate the introduction to a competent local company who will then deal with your enquiry directly, providing you with a quote and carrying out the work if you choose to proceed.
Sources and review
Checked against Fire Safety (England) Regulations 2022 reg.10, Regulatory Reform (Fire Safety) Order 2005 art.17, BS 8214 and Approved Document B on . We recheck this page against the legislation quarterly, and sooner if the law changes. Spotted something wrong? Tell us at enquiries@leicesterfireriskassessment.co.uk and we will correct it.
Fire Door Inspection nearby
Other duties at the same premises
This page is general information about fire safety law in England and Wales. It is not a fire risk assessment and it is not legal advice. Under the Regulatory Reform (Fire Safety) Order 2005 the Responsible Person must ensure an assessment is carried out by a competent person.