Fire detection and alarm systems must be maintained in efficient working order. BS 5839-1 recommends servicing by a competent person at intervals not exceeding six months, alongside the weekly call point test carried out by the occupier.
Duty summary
England & Wales
- Duty
- Fire Alarm Servicing
- Instrument
- article 17 of the Regulatory Reform (Fire Safety) Order 2005
- Also
- Health and Safety at Work etc. Act 1974
- Standard
- BS 5839-1:2025 for non-domestic systems and BS 5839-6 for domestic and HMO systems
- Frequency
- At intervals not exceeding six months, alongside the occupier's weekly call point test
- Carried out by
- A competent person
- Enforced by
- Leicestershire Fire and Rescue Service
- Guide price
- £90 – £250 per service visit
Guide price only. The firm we pass your enquiry to sets its own price once it knows the building.
For duty holders managing premises in Enderby, so that the reliable operation of fire detection and alarm systems is a fundamental responsibility. Whether your property is part of the village core, or within the large retail and distribution premises at Fosse Park and Grove Park office campuses, fire alarm servicing in Enderby is a critical aspect of fire safety management. These systems are essential for the early detection of fire and the safe evacuation of occupants in various settings, including shops, warehouses, offices, and residential blocks in the LE19 postcode district. Regular maintenance ensures that the system functions correctly when it is most needed, protecting lives and property. A fire alarm servicing in Enderby typically costs £90 to £250 per service visit. This figure depends on the size and complexity of the building and the system installed. The exact quote will be provided by the local firm we put you in touch with.
What Fire Alarm Servicing Covers
Fire alarm servicing involves a comprehensive inspection and testing of your fire detection and alarm system to ensure all components are functioning correctly and reliably. The scope of work typically includes:
- Testing of detectors: Heat, smoke, and multi-sensor detectors are tested for correct operation.
- Call point testing: Manual call points are activated to confirm they trigger the alarm.
- Sounder and beacon testing: Alarm sounders and visual indicators are checked for correct operation and audibility/visibility.
- Control panel inspection: The main control panel is examined for faults, correct power supply, and battery backup functionality.
- Wiring and connections: A visual inspection of wiring and connections is carried out where accessible.
- Logbook review: The fire alarm logbook is reviewed for previous faults, tests, and maintenance.
- System integrity: Checks are made to ensure the system is compliant with relevant standards and any changes to the building's use have been accounted for.
The price for servicing can vary based on several factors: the number of devices (detectors, call points, sounders) and panels within the system; the system category, for example, M (manual), L1 to L5 (life protection), P1 or P2 (property protection); whether the site is a single building or comprises several separate structures; the age of the control panel and the availability of spare parts; and the number of visits contracted per year.
How the enquiry works
- You send us details about your premises and fire alarm system in Enderby.
- We pass these details to a local fire safety firm that is able to carry out the work.
- That firm contacts you directly to discuss your specific requirements and provide a quote.
- You deal directly with the firm for the servicing work. We are an enquiry service, not the contractor.
Legal Obligations for Fire Alarm Servicing
The legal requirement for maintaining fire detection and alarm systems primarily stems from the Regulatory Reform (Fire Safety) Order 2005 (RRO). Specifically, Article 17 of the RRO places a duty on the responsible person to ensure that fire safety facilities, equipment, and devices are subject to a suitable system of maintenance and are maintained in an efficient state, in efficient working order, and in good repair. This is further supported by the general duties under the Health and Safety at Work etc. Act 1974.
For non-domestic premises, the industry standard for the design, installation, commissioning, and maintenance of fire detection and fire alarm systems is BS 5839-1:2025. For domestic premises and Houses in Multiple Occupation (HMOs), BS 5839-6 provides the relevant guidance. These British Standards recommend that fire detection and alarm systems are serviced by a competent person at intervals not exceeding six months. This regular servicing is in addition to the weekly call point test that should be carried out by the occupier or a designated person on site.
It is crucial that the assessment of your fire alarm system's maintenance needs is carried out by a competent person. This page provides general information and should not be taken as specific advice for your building. Enforcement of fire safety legislation in Enderby typically falls to the local fire and rescue service or the local authority, depending on the type of premises.
Questions duty holders ask
7 answers
How often should a fire alarm be serviced?
British Standards, specifically BS 5839-1 for non-domestic systems and BS 5839-6 for domestic and HMO systems, recommend that fire alarm systems are serviced by a competent person at least every six months. This regular maintenance ensures the system remains in efficient working order and helps to identify any potential faults before they become critical.
What is the weekly call point test?
The weekly call point test is a simple test carried out by the occupier or a designated person on site. It involves activating a different manual call point each week to ensure the alarm sounds correctly. This test is recorded in the fire alarm logbook and is a crucial part of ongoing system monitoring, complementing the professional six-monthly servicing.
What is a category L2 system?
A category L2 fire alarm system is designed to protect life in all areas of the building where a fire could start. This means detectors are installed in all circulation areas, escape routes, and in rooms that pose a high risk of fire. It provides a higher level of protection than an L3 system and is commonly found in larger commercial or public buildings.
Do I need a fire alarm logbook?
Yes, a fire alarm logbook is essential. It is a legal requirement under the Regulatory Reform (Fire Safety) Order 2005 to keep a record of all fire alarm tests, maintenance, and any faults. This logbook provides a clear history of the system's performance and maintenance, which can be reviewed during servicing or by enforcement officers.
Can any electrician service a fire alarm?
While a qualified electrician can carry out electrical work, fire alarm servicing requires specialist knowledge and competence in fire detection and alarm systems, as outlined in BS 5839. It is important to use a firm with specific expertise in fire alarm systems to ensure the servicing is carried out correctly and to the required standards.
How much does fire alarm servicing cost?
The cost for fire alarm servicing in Enderby typically ranges from £90 to £250 per service visit. This price can vary depending on factors such as the size and complexity of your building, the number of devices within the system, and the specific category of your fire alarm system. The local firm we connect you with will provide a tailored quote.
Are you the company that will carry out the servicing?
No, we are an enquiry service. Our role is to connect duty holders in Enderby with local fire safety firms that are qualified and experienced in fire alarm servicing. Once you submit your enquiry, we will pass your details to a suitable local firm, who will then contact you directly to discuss your needs and provide a quote.
Sources and review
Checked against Regulatory Reform (Fire Safety) Order 2005 art.17, Health and Safety at Work etc. Act 1974, BS 5839-1:2025 and BS 5839-6 on . We recheck this page against the legislation quarterly, and sooner if the law changes. Spotted something wrong? Tell us at enquiries@leicesterfireriskassessment.co.uk and we will correct it.
Fire Alarm Servicing nearby
Other duties at the same premises
This page is general information about fire safety law in England and Wales. It is not a fire risk assessment and it is not legal advice. Under the Regulatory Reform (Fire Safety) Order 2005 the Responsible Person must ensure an assessment is carried out by a competent person.