Fire detection and alarm systems must be maintained in efficient working order. BS 5839-1 recommends servicing by a competent person at intervals not exceeding six months, alongside the weekly call point test carried out by the occupier.
Duty summary
England & Wales
- Duty
- Fire Alarm Servicing
- Instrument
- article 17 of the Regulatory Reform (Fire Safety) Order 2005
- Also
- Health and Safety at Work etc. Act 1974
- Standard
- BS 5839-1:2025 for non-domestic systems and BS 5839-6 for domestic and HMO systems
- Frequency
- At intervals not exceeding six months, alongside the occupier's weekly call point test
- Carried out by
- A competent person
- Enforced by
- Leicestershire Fire and Rescue Service
- Guide price
- £90 – £250 per service visit
Guide price only. The firm we pass your enquiry to sets its own price once it knows the building.
For building owners, landlords, and managers in Coalville, so that the proper functioning of fire alarm systems is a critical responsibility. Fire alarm servicing in Coalville is essential for the safety of occupants in a range of premises, from the terraced housing and high street shops within the LE67 postcode district to the large distribution and manufacturing facilities on the town's outskirts. Given Coalville's history as a mining town, many buildings may have older infrastructure, making regular fire alarm maintenance particularly important to identify and address potential issues before they become serious. A fire alarm system provides early warning in the event of a fire, allowing for safe evacuation and minimising damage. Maintaining these systems in efficient working order is not only good practice but a legal requirement. A fire alarm servicing in Coalville typically costs £90 to £250 per service visit. This figure depends on the specifics of the building and the system, and the exact quote will be provided by the local firm we put you in touch with.
What Fire Alarm Servicing Covers
Fire alarm servicing involves a thorough inspection and testing of the entire fire detection and alarm system. A local firm will typically check all components, including control panels, detectors (smoke, heat, multi-sensor), manual call points, sounders, and visual alarms. They will ensure that all devices are functioning correctly, free from obstructions or damage, and that the system communicates effectively with any monitoring stations. The service often includes cleaning detectors, checking battery backups, and verifying the integrity of wiring.
The price of a fire alarm service can vary based on several factors:
- Number of devices and panels: More detectors, call points, and control panels will naturally increase the time and cost involved.
- System category: Different system categories, such as M (manual), L1 to L5 (life protection), or P1 and P2 (property protection), have varying levels of complexity and testing requirements. For example, an L1 system, designed to protect all areas of a building, will require more extensive servicing than a simpler L5 system.
- Site complexity: Whether the site is a single building or comprises several interconnected buildings will affect the scope of work.
- Age of the panel and availability of spare parts: Older systems may require more specialist knowledge or the sourcing of specific parts, which can impact cost.
- Number of visits contracted per year: Many firms offer discounts for annual contracts that include multiple service visits.
How the enquiry works
- You provide us with details about your fire alarm servicing needs in Coalville.
- We pass these details to a local, fire safety firm that serves the Coalville area.
- That firm will contact you directly to discuss your requirements and provide a tailored quote.
- You then deal directly with the firm for the service work. We are an enquiry service and do not carry out the work ourselves.
The Legal Position on Fire Alarm Servicing
As the duty holder, you have a legal responsibility to ensure the safety of people in your premises. Article 17 of the Regulatory Reform (Fire Safety) Order 2005 places a duty on you to ensure that fire safety facilities, including fire detection and alarm systems, are maintained in efficient working order and in good repair. This is further supported by the Health and Safety at Work etc. Act 1974, which requires employers to ensure, so far as is reasonably practicable, the health, safety and welfare of their employees and others who may be affected by their work activities.
For non-domestic systems, the British Standard BS 5839-1:2025 provides detailed recommendations for the design, installation, commissioning, and maintenance of fire detection and fire alarm systems. For domestic and HMO systems, BS 5839-6 offers similar guidance. BS 5839-1:2025 specifically recommends that fire alarm systems are serviced by a competent person at intervals not exceeding six months. This is in addition to the weekly call point test that should be carried out by the occupier or a nominated responsible person.
It is crucial that any assessment and maintenance of your fire alarm system is carried out by a competent person. This page provides general information and should not be considered specific advice for your particular building or situation. Enforcement of fire safety regulations in Coalville is typically handled by the local fire and rescue service or the local authority, as appropriate to the premises type.
Questions duty holders ask
7 answers
How often should a fire alarm be serviced?
British Standard BS 5839-1:2025 recommends that fire alarm systems in non-domestic premises are serviced by a competent person at least every six months. This regular servicing ensures the system remains in efficient working order and complies with legal requirements.
What is the weekly call point test?
The weekly call point test is a simple functional test carried out by the occupier or a nominated responsible person. It involves activating a different manual call point each week to ensure the alarm sounds correctly. The results should be recorded in the fire alarm logbook.
What is a category L2 system?
A category L2 fire alarm system is designed to provide automatic fire detection in all escape routes and rooms adjoining escape routes, along with high-hazard areas. It aims to protect life by giving early warning of fire in critical areas.
Do I need a fire alarm logbook?
Yes, a fire alarm logbook is essential. It provides a comprehensive record of all tests, services, faults, and repairs carried out on your fire alarm system. This logbook demonstrates compliance with fire safety regulations and helps track the system's history.
Can any electrician service a fire alarm?
While some electricians may have basic electrical knowledge, fire alarm servicing requires specialist expertise in fire detection systems. It is recommended that servicing is carried out by a competent person or a firm with specific experience and qualifications in fire alarm maintenance, in line with BS 5839 standards.
What does fire alarm servicing cost?
The cost for a fire alarm servicing in Coalville typically ranges from £90 to £250 per service visit. This price can vary depending on factors such as the size and complexity of your building, the number of devices, and the specific category of your fire alarm system.
How do I get a quote for fire alarm servicing?
To get a quote, you can provide us with your details. We will then pass your enquiry to a local fire safety firm in the Coalville area. That firm will contact you directly to discuss your specific needs and provide you with a tailored quotation for the servicing of your fire alarm system.
Sources and review
Checked against Regulatory Reform (Fire Safety) Order 2005 art.17, Health and Safety at Work etc. Act 1974, BS 5839-1:2025 and BS 5839-6 on . We recheck this page against the legislation quarterly, and sooner if the law changes. Spotted something wrong? Tell us at enquiries@leicesterfireriskassessment.co.uk and we will correct it.
Fire Alarm Servicing nearby
Other duties at the same premises
This page is general information about fire safety law in England and Wales. It is not a fire risk assessment and it is not legal advice. Under the Regulatory Reform (Fire Safety) Order 2005 the Responsible Person must ensure an assessment is carried out by a competent person.